Globe Control Valve
Flow, Pressure, Level, Temperature Control Valves
100% & 30% Feed Water Control Valve
Start-up Vent Valve
Attemperator Control Valve
Boiler Feed Pump Recirculation Valve
Deaerator Level & Pressure Control Valve
Lined Globe Control Valve
PFA Lined valves
Size: 1’’ thru8’’ (DN 25 to DN 200)
Body Rating: ANSI 150#
Leakage Class: Class VI (Soft seated)
Flow Characteristic: Equal percentage
Temperature range: -60°C to +200°C
Comes with multispring actuator
Smallest travel length
Bellow sealed bonnets available
Actuated Lined Ball Valve
PFA Lined Ball Valve
Valve Size: ½” thru 24” upto 300#
PFA Lined Valve Size: ½” thru 8” 150#
Leakage Class: VI (Soft Seated)
Flow Characteristics: ON-OFF/ Throttiling
Actuated Lined Butterfly Valve
Valve Size: 2” thru 24” 150#
Standard as well as PFA Lined Ball Valves
Leakage Class’: VI (Soft Seated)
Flow Characteristics: Throttling, ON‐OFF
Electric, Pneumatic or Hydraulic actuators available
3 Way Control Valve
Flow Diverting and Flow mixing 3 way Globe valves.
Line Sizes: ½” thru 12” (15NB thru 300NB)
Body rating upto 300#
Temperature: -190 thru +590 degC
Application: Thermic Fluid, Steam, Organic Liquid, Glycol, Contaminated Water, CIP etc
Actuated Flush Bottom Valve
Valve Size: 1” thru 8” (DN 25 thru DN 200)
Pressure Rating: upto 600#
Plug Options: Contour with OPENING into the vessel or within the valve body
Flow Characteristics: ON – OFF
Linear/ Rotary Electro Pneumatic Positioner
With or without Position Transmitter
Pneumatic Actuated 2p/ 3p On/ Off Ball Valves
Size: 15mm to 200mm
Pneumatic Actuated 3 Way On/ Off Ball Valves
Size: 15mm to 200mm
Solenoid Valves
5/2 way Single Coil
3/2 way Single Coil
5/2 way Double Coil
3/2 way Double Coil
2 Way Angle Type Single Or Double Acting On/ Off Valve
Size: 15MMto 100 mm
Pressure Reducing And Desuperheating Station (PRDS)
Follow Our Socials
Steam Water Analysis
You are here:
Home
1
/
Control Valves
Online Analysers For Steam Water Analysis
pH / ORP TRANSMITTER (AC or DC-4wire)
Model: AI201
Industrial Process Applications
pH Range: 0-14pH
ORP Range: -2000mV to +2000mV
Power Supply: 90-260 VAC / 24VDC
Outputs: 4-20mA, Relays, MODBUS
Temperature Compensation: Auto/ Manual
pH Accuracy: ± 01pH
ORP Accuracy: ± 1mV
IP65 Enclosure
pH / ORP TRANSMITTER (2wire)
Model: AI201- 2wire
Industrial Process Applications
pH Range: 0-14pH
ORP Range: -2000mV to +2000mV
Power Supply: 24 VDC
Outputs: 4-20mA Loop Powered (2 Wire)
Temperature Compensation: Auto/ Manual
pH Accuracy: ± 01pH
ORP Accuracy: ± 1mV
IP65 Enclosure
pH / ORP SENSOR
Ryton Body MoC pH/ ORP sensor with temperature compensation
CONDUCTIVITY TRANSMITTER (AC or DC 4wire)
Model: AI401
Industrial Process Applications
Conductivity Range: 0 µS through 2000 mS
TDS Range: 0 to 1,33,000 ppm
Power Supply: 90-260 VAC/ 24 VDC
Outputs: 4-20mA, Relays, MODBUS
Temperature Compensation: Auto/ Manual
Accuracy: ± 1% of FS
IP65 Enclosure
CONDUCTIVITY TRANSMITTER (2wire)
Model: AI401- 2wire
Industrial Process and Waste Water Applications
Conductivity Range: 0 µS through 200 mS
TDS Range: 0 to 99,999 ppm
Power Supply: 24 VDC
Outputs: 4-20mA Loop Powered (2 Wire)
Temperature Compensation: Auto/ Manual
Accuracy: ± 1% of FS
IP65 Enclosure
CONDUCTIVITY SENSOR
SS body conductivity sensors for K=0.01 and K=0.1 cell constant
SS/ Nylon body conductivity sensors for K=0.5 & K=1 or 10 cell constant
ONLINE TRACE DISSOLVED OXYGEN ANALYSER
Measuring Range: 0.1ppb to 50ppm
Measuring Principle: Optical/ Amperometric
Temperature Compensation: Automatic
Sensor body MoC: SS316L
Measuring Temperature range: 0-80degc
Sensor Operating Pressure: 0.2 to 9 bar
The transmitter has sensor diagnostic capability
The transmitter displays the time to calibrate the sensor as well as the time to do maintenance on the membrane.
Accuracy: 0.5% of the measured value
Resolution: 0.001/0.01/ 0.1/1- Auto selectable
ONLINE SILICA ANALYSER
Measuring Principle: Colorimetric
Programmable measuring time: 15 minutes
Calibration Range: 0-200 or 0-500 ppb
(alternative calibration ranges available on request)
Accuracy (0-200 ppb): better than 2% or +/- 0.5 ppb whichever is greater
Detection Limit (0-200 ppb):< 1.5 ppb (calculated as for EPA p. 136 appendix B)
Output Signal: 4-20 mA
Sample Temperature: 10 °C – 30 °C
ONLINE PHOSPHATE ANALYSER
Measuring Principle: Colorimetric, Molybdate ascorbic acid method
Measuring Interval: Programmable
Measuring Time: 5 minutes
MEASURING RANGE: 0-0.2/0.7/2/5/10/20/100/200 ppm (other ranges available on request)
Detection Limit: Typically better 2% of the full scale
Output Signal: 4-20 mA
Sample Temperature: 10 °C – 30 °C
ONLINE SODIUM ANALYSER
Measuring Principle: Ion Selective Electrode (ISE)
Measuring Cell: flow cell including combined measuring electrode
Measurement Time: 3-5minutes depending on the range
Measuring Range: 1-10 mg/L as sodium
Detection limit: better 3% of the full scale
Output signal: 4-20 ma
Sample temperature: 10°c – 30 °C
ONLINE CHLORIDE ANALYSER
Measuring Principle: Chloride Ion Selective Electrode (ISE)
Measurement Time: 45 minutes programmable between 15 minutes to 1 hr
Measuring Range: 0-300 ppb as Cl-
Detection Limit: 0.5ppb
Output Signal: 4-20 mA
Sample Temperature: 10°c – 45 °C
ONLINE HYDRAZINE ANALYSER
Measuring Principle: Colorimetric, p-dimethylaminobenzaldehyde
Colorimeter: Dual Beam, Silicon Detector
Measurement Type: Cyclic
Measuring Interval: Programmable
Measuring Time: 8- 10 minutes depending on the range
Measuring Range: 0–0.1 up to 5 ppm, other range available on request
Detection Limit: better 2% of the full scale
Output Signal: 4-20 mA
Sample Temperature: 10 °C – 30 °C
ONLINE IRON ANALYSER
Measuring Principle: Colorimetric; acidic digestion + TPTZ method
Colorimeter: Dual Beam, Silicon Detector
Measurement Type: Cyclic
Measuring Interval: Programmable
Measuring Time: 23 minutes depending on the range
Measuring Range: 0- 2/ 5/ 10 ppm, other range available on request
Detection Limit: better 2% of the full scale
Output Signal: 4-20 mA