• Water Treatment

Online Analysers For Water Treatment Plants

pH / ORP TRANSMITTER (AC or DC-4wire)

Model: AI201

  • Industrial Process Applications
  • pH Range: 0-14pH
  • ORP Range: -2000mV to +2000mV
  • Power Supply: 90-260 VAC / 24VDC
  • Outputs: 4-20mA, Relays, MODBUS
  • Temperature Compensation: Auto/ Manual
  • pH Accuracy: ± 0.01pH
  • ORP Accuracy: ± 1mV
  • IP65 Enclosure

pH / ORP TRANSMITTER (2wire)

Model: AI201- 2wire

  • Industrial Process and Waste Water Applications
  • pH Range: 0-14pH
  • ORP Range: -2000mV to +2000mV
  • Power Supply: 24 VDC
  • Outputs: 4-20mA Loop Powered (2 Wire)
  • Temperature Compensation: Auto/ Manual
  • pH Accuracy: ± 0.01pH
  • ORP Accuracy: ± 1mV
  • IP65 Enclosure

pH / ORP Sensors

pH / ORP SENSOR W/O TEMP

  • PVC body MoC pH/ ORP sensor without temperature compensation

pH / ORP SENSOR WITH TEMP COMPENSATION

  • Ryton Body MoC pH/ ORP sensor with temperature compensation

pH / ORP SENSOR FOR ULTRAPURE WATER

  • pH Sensor with refillable liquid electrolyte for Ultrapure/ Very Low Conductivity water (below 1 µS/cm) application

CONDUCTIVITY TRANSMITTER (AC or DC 4wire)

Model: AI401

  • Industrial Process Applications
  • Conductivity Range: 0 µS through 2000 mS
  • TDS Range: 0 to 1,33,000 ppm
  • Power Supply: 90-260 VAC/ 24 VDC
  • Outputs: 4-20mA, Relays, MODBUS
  • Temperature Compensation: Auto/ Manual
  • Accuracy: ± 1% of FS
  • IP65 Enclosure

CONDUCTIVITY TRANSMITTER (2wire)

Model: AI401- 2wire

  • Industrial Process and Waste Water Applications
  • Conductivity Range: 0 µS through 200 mS
  • TDS Range: 0 to 99,999 ppm
  • Power Supply: 24 VDC
  • Outputs: 4-20mA Loop Powered (2 Wire)
  • Temperature Compensation: Auto/ Manual
  • Accuracy: ± 1% of FS

CONDUCTIVITY SENSORS

  • SS body conductivity sensors for K=0.01 and K=0.1 cell constant
  • SS/ Nylon body conductivity sensors for K=0.5 & K=1 or 10 cell constant

INDUCTIVE / TORROIDAL CONDUCTIVITY SENSOR

  • PP and PVDF body non contact toroidal conductivity sensors for wide range conductivity measurement (from µS to mS)

TURBIDITY ANALYSER

Model: AI811

  • Industrial Process and Treated Water Applications
  • Turbidity Range: 0-3000 NTU
  • Power Supply: 100-240 VAC
  • Outputs: 4-20mA
  • Turbidity Accuracy: ± 2% of FS
  • Resolution:
  • For Range 0 to 99.9 NTU: 0.1
  • For Range 100 to 499 NTU: 1
  • For Range 500 to 3000 NTU: 5
  • IP65 Enclosure

SENSOR

  • Nephelometric 90Deg Light Scattering Technology
  • Body MoC: SS
  • Operating Temperature: upto 40 DegC
  • Comes with integral 3 mtrs cable
  • IP68 Sensor enclosure

TSS ANALYSER

Model: AI841

  • Industrial Process and Treated Water Applications
  • TSS Range: 0-1000 mg/L (ppm)
  • Power Supply: 100-240 VAC
  • Outputs: 4-20mA & Relays
  • Accuracy: <5% of the reading
  • IP65 Enclosure

SENSOR

  • Body MoC of the Sensor: SS316 or (SS Duplexsuitable for sea waterapplications and water with chloride content)
  • Sensor comes with 9 mtrs integral cable
  • IP68 Sensor enclosure

CHLORINE ANALYSER

Model: AI821

  • Free Chlorine (Constant Voltage/ Amperometric Type)
  • Measuring Parameters: Free Chlorine/Ozone/Chlorine Dioxide
  • Outputs: 4-20mA output, Relays& RS485
  • Power Supply: 90-260 VAC
  • pH compensation: Manual
  • IP65 Enclosure

Measuring Range:

  • Free Chlorine: 0- 20 ppm
  • Chlorine di Oxide: 0- 2 ppm
  • Dissolved Ozone: 0- 2 ppm
  • pH compensation: Manual

CHLORINE SENSOR

  • Free chlorine (FRC)sensor for clean/drinking water application
  • Operating Temperature: 0 – 60°C
  • Pressure: 0 to 5 Bar – Min. Flowrate: 0.02 m/s
  • Body Material: Glass
  • Cable Length: 5m with bare wire

ONLINE SILICA ANALYSER (PPM)

  • Measuring Principle: Colorimetric
  • Programmable measuring time: 15 minutes
  • Calibration Range: 0-200 ppm
  • (alternative calibration ranges available on request)
  • Output Signal: 4-20 mA
  • Sample Temperature: 10°C-30°C

ONLINE TOC ANALYSER (PPM)

  • Measuring Principle: UV promoted oxidation, CO2 detection by Non Dispersive Infrared Detector (NDIR)
  • Programmable measuring time: 15 minutes
  • Calibration Range: 0-20 ppm(alternative calibration ranges available on request)
  • Output Signal: 4-20 mA
  • Sample Temperature: 10 °C – 30 °C

IRON ANALYSER

  • Colorimetric; acidic digestion + TPTZ method
  • Measuring Time: 23 minutes depending on the range
  • Measuring Range: 0-/2/5/10/ ppm, other ranges available on request
  • Min. Detection Limit: typically better than 2% of the FS
  • Output: Analog 4-20mA

HARDNESS/ ALKALINITY ANALYSER

  • Calorimetric measurement principle
  • Country of Origin: Italy
  • Output: 2 nos of programmable relay outputs and 1 no. of analog 4 -20mA output.
  • Range:

  • Water Hardness: 50 through 500 ppm
  • Alkalinity: 20 through 400ppm

OTHER SPECIAL ANALYSERS:

Bromine, Ammonia, Chloride, Chromium, Copper, Cyanide, Nickel, Manganese, Magnesium, Fluoride, Aluminium, Total Nitrogen, Zinc, Phosphorus, etc…