• Steam Water Analysis

Online Analysers For Steam Water Analysis

pH / ORP TRANSMITTER (AC or DC-4wire)

Model: AI201

  • Industrial Process Applications
  • pH Range: 0-14pH
  • ORP Range: -2000mV to +2000mV
  • Power Supply: 90-260 VAC / 24VDC
  • Outputs: 4-20mA, Relays, MODBUS
  • Temperature Compensation: Auto/ Manual
  • pH Accuracy: ± 01pH
  • ORP Accuracy: ± 1mV
  • IP65 Enclosure

pH / ORP TRANSMITTER (2wire)

Model: AI201- 2wire

  • Industrial Process Applications
  • pH Range: 0-14pH
  • ORP Range: -2000mV to +2000mV
  • Power Supply: 24 VDC
  • Outputs: 4-20mA Loop Powered (2 Wire)
  • Temperature Compensation: Auto/ Manual
  • pH Accuracy: ± 01pH
  • ORP Accuracy: ± 1mV
  • IP65 Enclosure

pH / ORP SENSOR

  • Ryton Body MoC pH/ ORP sensor with temperature compensation

CONDUCTIVITY TRANSMITTER (AC or DC 4wire)

Model: AI401

  • Industrial Process Applications
  • Conductivity Range: 0 µS through 2000 mS
  • TDS Range: 0 to 1,33,000 ppm
  • Power Supply: 90-260 VAC/ 24 VDC
  • Outputs: 4-20mA, Relays, MODBUS
  • Temperature Compensation: Auto/ Manual
  • Accuracy: ± 1% of FS
  • IP65 Enclosure

CONDUCTIVITY TRANSMITTER (2wire)

Model: AI401- 2wire

  • Industrial Process and Waste Water Applications
  • Conductivity Range: 0 µS through 200 mS
  • TDS Range: 0 to 99,999 ppm
  • Power Supply: 24 VDC
  • Outputs: 4-20mA Loop Powered (2 Wire)
  • Temperature Compensation: Auto/ Manual
  • Accuracy: ± 1% of FS
  • IP65 Enclosure

CONDUCTIVITY SENSOR

  • SS body conductivity sensors for K=0.01 and K=0.1 cell constant
  • SS/ Nylon body conductivity sensors for K=0.5 & K=1 or 10 cell constant

ONLINE TRACE DISSOLVED OXYGEN ANALYSER

  • Measuring Range: 0.1ppb to 50ppm
  • Measuring Principle: Optical/ Amperometric
  • Temperature Compensation: Automatic
  • Sensor body MoC: SS316L
  • Measuring Temperature range: 0-80degc
  • Sensor Operating Pressure: 0.2 to 9 bar
  • The transmitter has sensor diagnostic capability
  • The transmitter displays the time to calibrate the sensor as well as the time to do maintenance on the membrane.
  • Accuracy: 0.5% of the measured value
  • Resolution: 0.001/0.01/ 0.1/1- Auto selectable

ONLINE SILICA ANALYSER

  • Measuring Principle: Colorimetric
  • Programmable measuring time: 15 minutes
  • Calibration Range: 0-200 or 0-500 ppb
  • (alternative calibration ranges available on request)
  • Accuracy (0-200 ppb): better than 2% or +/- 0.5 ppb whichever is greater
  • Detection Limit (0-200 ppb):< 1.5 ppb (calculated as for EPA p. 136 appendix B)
  • Output Signal: 4-20 mA
  • Sample Temperature: 10 °C – 30 °C

ONLINE PHOSPHATE ANALYSER

  • Measuring Principle: Colorimetric, Molybdate ascorbic acid method
  • Measuring Interval: Programmable
  • Measuring Time: 5 minutes
  • MEASURING RANGE: 0-0.2/0.7/2/5/10/20/100/200 ppm (other ranges available on request)
  • Detection Limit: Typically better 2% of the full scale
  • Output Signal: 4-20 mA
  • Sample Temperature: 10 °C – 30 °C

ONLINE SODIUM ANALYSER

  • Measuring Principle: Ion Selective Electrode (ISE)
  • Measuring Cell: flow cell including combined measuring electrode
  • Measurement Time: 3-5minutes depending on the range
  • Measuring Range: 1-10 mg/L as sodium
  • Detection limit: better 3% of the full scale
  • Output signal: 4-20 ma
  • Sample temperature: 10°c – 30 °C

ONLINE CHLORIDE ANALYSER

  • Measuring Principle: Chloride Ion Selective Electrode (ISE)
  • Measurement Time: 45 minutes programmable between 15 minutes to 1 hr
  • Measuring Range: 0-300 ppb as Cl-
  • Detection Limit: 0.5ppb
  • Output Signal: 4-20 mA
  • Sample Temperature: 10°c – 45 °C

ONLINE HYDRAZINE ANALYSER

  • Measuring Principle: Colorimetric, p-dimethylaminobenzaldehyde
  • Colorimeter: Dual Beam, Silicon Detector
  • Measurement Type: Cyclic
  • Measuring Interval: Programmable
  • Measuring Time: 8- 10 minutes depending on the range
  • Measuring Range: 0–0.1 up to 5 ppm, other range available on request
  • Detection Limit: better 2% of the full scale
  • Output Signal: 4-20 mA
  • Sample Temperature: 10 °C – 30 °C

ONLINE IRON ANALYSER

  • Measuring Principle: Colorimetric; acidic digestion + TPTZ method
  • Colorimeter: Dual Beam, Silicon Detector
  • Measurement Type: Cyclic
  • Measuring Interval: Programmable
  • Measuring Time: 23 minutes depending on the range
  • Measuring Range: 0- 2/ 5/ 10 ppm, other range available on request
  • Detection Limit: better 2% of the full scale
  • Output Signal: 4-20 mA

SWAS PANEL