Analysers for Process
You are here: Home1 / Analysers for Process

Online Analysers For Process Applications
pH / ORP TRANSMITTER
(AC or DC-4wire)
Model: AI201
- Industrial Process Applications
- pH Range: 0-14pH
- ORP Range: -2000mV to +2000mV
- Power Supply: 90-260 VAC / 24VDC
- Outputs: 4-20mA, Relays, MODBUS
- Temperature Compensation: Auto/ Manual
- pH Accuracy: ± 01pH
- ORP Accuracy: ± 1mV
- IP65 Enclosure
pH / ORP TRANSMITTER (2-wire)
Model: AI201- 2wire
- Industrial Process Applications
- pH Range: 0-14pH
- ORP Range: -2000mV to +2000mV
- Power Supply: 24 VDC
- Outputs: 4-20mA Loop Powered (2 Wire)
- Temperature Compensation: Auto/ Manual
- pH Accuracy: ± 01pH
- ORP Accuracy: ± 1mV
- IP65 Enclosure
pH / ORP TRANSMITTER (FLP)
Model: AI201-FLP
- FlameProof enclosures
- Industrial Process Applications
- pH Range: 0-14pH
- ORP Range: -2000mV to +2000mV
- Power Supply: 24 VDC
- Outputs: 4-20mA Loop Powered (2 Wire)
- Temperature Compensation: Auto/ Manual
- pH Accuracy: ± 01pH
- ORP Accuracy: ± 1mV
- IP65 Enclosure
- PVC body MoC pH/ ORP sensor without temperature compensation
- Ryton Body MoC pH/ ORP sensor with temperature compensation for all general applications
- Special category pH sensors with Kynar body MoC for chemical services
CONDUCTIVITY TRANSMITTER (AC or DC 4wire)
Model: AI401
- Industrial Process Applications
- Conductivity Range: 0 µS through 2000 mS
- TDS Range: 0 to 1,33,000 ppm
- Power Supply: 90-260 VAC/ 24 VDC
- Outputs: 4-20mA, Relays, MODBUS
- Temperature Compensation: Auto/ Manual
- Accuracy: ± 1% of FS
- IP65 Enclosure
CONDUCTIVITY TRANSMITTER (2wire)
Model: AI401- 2wire
- Industrial Process and Waste Water Applications
- Conductivity Range: 0 µS through 200 mS
- TDS Range: 0 to 99,999 ppm
- Power Supply: 24 VDC
- Outputs: 4-20mA Loop Powered (2 Wire)
- Temperature Compensation: Auto/ Manual
- Accuracy: ± 1% of FS
- IP65 Enclosure
- SS body conductivity sensors for K=0.01 and K=0.1 cell
- Nylon body conductivity sensors for K=0.5 & K=1 or 10 cell constant
- PP and PFA body non contact toroidal conductivity sensors for wide range conductivity measurement.
- Conductivity Range: 0 – 2/20/200/2000 mS/cm
- Salinity Range: 0 – 72 g/Kg
CONCENTRATION ANALYSER
Model: AI401 (AC or DC 4wire)
- Industrial Process Applications
- Power Supply: 90-260 VAC/ 24 VDC
- Outputs: 4-20mA, Relays, MODBUS
- Temperature Compensation: Auto/ Manual
- Accuracy: ± 1% of FS
- IP65 Enclosure
SENSOR
Model: AI401 (AC or DC 4wire)
- PP and PFA body Toroidal Conductivity sensors for measuring the Concentration of Acids & bases.
- Acid-Base Parameters: HCL /NaOH /KOH /H2SO4 /NaCl /HNO3
Range :
- HCL: 0.00 – 20.00; 25.00 – 40.00%
- HNO3: 0.00 – 25.00%
- NaOH: 0.00 – 18.00; 0.00 – 40.00%
- KOH: 0.00 – 30.00 %
- H2SO4: 0.00 – 25.00; 35.00 – 100.0%
- NaCl: 0.00 – 30.00%
Scroll to top