• Analysers for Process

Online Analysers For Process Applications

pH / ORP TRANSMITTER
(AC or DC-4wire)

Model: AI201

  • Industrial Process Applications
  • pH Range: 0-14pH
  • ORP Range: -2000mV to +2000mV
  • Power Supply: 90-260 VAC / 24VDC
  • Outputs: 4-20mA, Relays, MODBUS
  • Temperature Compensation: Auto/ Manual
  • pH Accuracy: ± 01pH
  • ORP Accuracy: ± 1mV
  • IP65 Enclosure

pH / ORP TRANSMITTER (2-wire)

Model: AI201- 2wire

  • Industrial Process Applications
  • pH Range: 0-14pH
  • ORP Range: -2000mV to +2000mV
  • Power Supply: 24 VDC
  • Outputs: 4-20mA Loop Powered (2 Wire)
  • Temperature Compensation: Auto/ Manual
  • pH Accuracy: ± 01pH
  • ORP Accuracy: ± 1mV
  • IP65 Enclosure

pH / ORP TRANSMITTER (FLP)

Model: AI201-FLP

  • FlameProof enclosures
  • Industrial Process Applications
  • pH Range: 0-14pH
  • ORP Range: -2000mV to +2000mV
  • Power Supply: 24 VDC
  • Outputs: 4-20mA Loop Powered (2 Wire)
  • Temperature Compensation: Auto/ Manual
  • pH Accuracy: ± 01pH
  • ORP Accuracy: ± 1mV
  • IP65 Enclosure

pH / ORP Sensors

  • PVC body MoC pH/ ORP sensor without temperature compensation

  • Ryton Body MoC pH/ ORP sensor with temperature compensation for all general applications
  • Special category pH sensors with Kynar body MoC for chemical services

Accessories

PP Flow Cell

SS Flow Cell

PTFE Lined Dip Rods

Retractable Assembly

CONDUCTIVITY TRANSMITTER (AC or DC 4wire)

Model: AI401

  • Industrial Process Applications
  • Conductivity Range: 0 µS through 2000 mS
  • TDS Range: 0 to 1,33,000 ppm
  • Power Supply: 90-260 VAC/ 24 VDC
  • Outputs: 4-20mA, Relays, MODBUS
  • Temperature Compensation: Auto/ Manual
  • Accuracy: ± 1% of FS
  • IP65 Enclosure

CONDUCTIVITY TRANSMITTER (2wire)

Model: AI401- 2wire

  • Industrial Process and Waste Water Applications
  • Conductivity Range: 0 µS through 200 mS
  • TDS Range: 0 to 99,999 ppm
  • Power Supply: 24 VDC
  • Outputs: 4-20mA Loop Powered (2 Wire)
  • Temperature Compensation: Auto/ Manual
  • Accuracy: ± 1% of FS
  • IP65 Enclosure

Conductivity Sensors

  • SS body conductivity sensors for K=0.01 and K=0.1 cell

  •  Nylon body conductivity sensors for K=0.5 & K=1 or 10 cell constant

  • PP and PFA body non contact toroidal conductivity sensors for wide range conductivity measurement.
  • Conductivity Range: 0 – 2/20/200/2000 mS/cm
  • Salinity Range: 0 – 72 g/Kg

CONCENTRATION ANALYSER

Model: AI401 (AC or DC 4wire)

  • Industrial Process Applications
  • Power Supply: 90-260 VAC/ 24 VDC
  • Outputs: 4-20mA, Relays, MODBUS
  • Temperature Compensation: Auto/ Manual
  • Accuracy: ± 1% of FS
  • IP65 Enclosure

SENSOR

Model: AI401 (AC or DC 4wire)

  • PP and PFA body Toroidal Conductivity sensors for measuring the Concentration of Acids & bases.
  • Acid-Base Parameters: HCL /NaOH /KOH /H2SO4 /NaCl /HNO3

Range :

  • HCL: 0.00 – 20.00; 25.00 – 40.00%
  • HNO3: 0.00 – 25.00%
  • NaOH: 0.00 – 18.00; 0.00 – 40.00%
  • KOH: 0.00 – 30.00 %
  • H2SO4: 0.00 – 25.00; 35.00 – 100.0%
  • NaCl: 0.00 – 30.00%