• Pharma & Biotech

ONLINE ANALYSERS FOR PHARMA & BIOTECH

pH / ORP TRANSMITTERS- 4 wire

Model: AI201 (AC or DC-4wire)

  • Industrial Process Applications
  • pH Range: 0-14pH
  • ORP Range: -2000mV to +2000mV
  • Power Supply: 90-260 VAC / 24VDC
  • Outputs: 4-20mA, Relays, MODBUS
  • Temperature Compensation: Auto/ Manual
  • pH Accuracy: ± 01pH
  • ORP Accuracy: ± 1mV
  • IP65 Enclosure

pH / ORP TRANSMITTERS – 2 wire

Model: AI201- 2wire

  • Industrial Process Applications
  • pH Range: 0-14pH
  • ORP Range: -2000mV to +2000mV
  • Power Supply: 24 VDC
  • Outputs: 4-20mA Loop Powered (2 Wire)
  • Temperature Compensation: Auto/ Manual
  • pH Accuracy: ± 01pH
  • ORP Accuracy: ± 1mV
  • IP65 Enclosure

pH / ORP TRANSMITTERS-FlameProof

Model: AI201-FLP

  • Flame Proof enclosure
  • Industrial Process Applications
  • pH Range: 0-14pH
  • ORP Range: -2000mV to +2000mV
  • Power Supply: 24 VDC
  • Outputs: 4-20mA Loop Powered (2 Wire)
  • Temperature Compensation: Auto/ Manual
  • pH Accuracy: ± 01pH
  • ORP Accuracy: ± 1mV
  • IP65 Enclosure

pH / ORP SENSORS

pH / ORP SENSORS- Autoclavable and steam sterilisable

  • Autoclavable and steam sterilisable pH & redox electrodes
  • Steam sterilizable to 135° C
  • Pressure: upto 10 bar
  • Electrodes are available in a 12 mm body with a PG13.5 mounting thread and insertion lengths up to 420 mm

pH / ORP SENSORS- Special Purpose

  • Ryton or Kynar body MoC sensors for harsh chemical services

pH / ORP SENSORS- General Purpose

  • Ryton body MoC pH sensors for standard applications

ACCESSORIES

Manual Retractable Assembly

Auto Retractable Assembly

Dip Rods- PTFE Coated with custom end

Sanitary Adapters

PTFE/ PP Flow through cell

CONDUCTIVITY ANALYSER for CIP APPLICATION

Model: AI401 (AC or DC 4wire)

  • Industrial Process Applications
  • Conductivity Range: 0 µS through 2000 mS
  • TDS Range: 0 to 1,33,000 ppm
  • Power Supply: 90-260 VAC/ 24 VDC
  • Outputs: 4-20mA, Relays, MODBUS
  • Temperature Compensation: Auto/ Manual
  • Accuracy: ± 1% of FS
  • IP65 Enclosure
  • PFA body non contact toroidal conductivity sensors for Concentration/ Conductivity measurement during CIP.
  • Conductivity Range: 0 – 2/20/200/2000 mS/cm
  • Salinity Range: 0 – 72 g/Kg

CONDUCTIVITY ANALYSER FOR PURE WATER

Model: AI401 (AC or DC 4wire)

  • Industrial Process Applications
  • Conductivity Range: 0 µS through 2000 mS
  • TDS Range: 0 to 1,33,000 ppm
  • Power Supply: 90-260 VAC/ 24 VDC
  • Outputs: 4-20mA, Relays, MODBUS
  • Temperature Compensation: Auto/ Manual
  • Accuracy: ± 1% of FS
  • IP65 Enclosure

Conductivity Sensor

  • SS body sensors for K=0.01 and K=0.1 cell constant

ONLINE CHLORINE / OZONE ANALYSER

Model: AI821

  • Free Chlorine (Constant Voltage/ Amperometric Type)
  • Measuring Parameters: Free Chlorine/ Ozone/ Chlorine Dioxide
  • Outputs: 4-20mA output, Relays & RS485
  • Power Supply: 90-260 VAC

Measuring Range :

  • Free Chlorine: 0- 20 ppm
  • Chlorine di Oxide: 0- 2 ppm
  • Dissolved Ozone: 0- 2 ppm
  • pH compensation: Manual
  • Power Supply: 90 – 260 VAC

CHLORINE SENSOR :

  • Free chlorine sensor for clean/drinking water application
  • Operating Temperature: 0 – 60°C
  • Pressure: 0 to 5 Bar – Min. Flowrate: 0.02 m/s
  • Body Material: Glass
  • Cable Length: 5m with bare wire
  • Sensor Connection: PG13.5 thread

Dissolved Oxygen Analyser

Model: AI801

  • Fermentation Applications
  • DO Range: 0-300% or 0-24 ppm
  • Power Supply: 115 VAC or260 VAC
  • Outputs: 4-20mA, Relays
  • Temperature Compensation: Auto
  • Calibration: 2 point
  • DO Accuracy: ± 0.1 ppm
  • IP65 Enclosure

Dissolved Oxygen Sensor

  • Autoclavable and steam sterilisable polarographic Dissolved Oxygen sensors
  • Comes with 12, 19 & 25 mm diameter
  • Fits in any make fermenters worldwide
  • Customised probe lengths
  • Steam sterilizable to 135° C
  • Pressure: upto 10 bar

AUTO / MANUAL RETRACTABLE SYSTEM

Auto Retractable System

  • Automatic Cleaning with water/solvents
  • Automatic Calibration of sensor with buffer solutions
  • Sensor can be replaced easily without interrupting the process / flow
  • Can perform SIP before inserting the sensor into bioprocess Fermenter

Turbidity Analyser

AI811

  • Industrial Process and Treated Water Applications
  • Turbidity Range: 0-3000 NTU
  • Power Supply: 100-240 VAC
  • Outputs: 4-20mA
  • Turbidity Accuracy: ± 2% of FS
  • Resolution:
  • For Range 0 to 99.9 NTU: 0.1
  • For Range 100 to 499 NTU: 1
  • For Range 500 to 3000 NTU: 5
  • IP65 Enclosure

Sensor

  • Country of Origin: Japan
  • Nephelometric 90Deg Light Scattering Technology
  • Body MoC: SS
  • Operating Temperature: upto 40 DegC
  • Comes with integral 3 mtrs cable
  • IP68 Sensor enclosure

TSS Analyser

AI841

  • Industrial Process and Treated Water Applications
  • TSS Range: 0-1000 mg/L (ppm)
  • Power Supply: 100-240 VAC
  • Accuracy: <5% of the reading
  • Outputs: 4-20mA & Relays

Sensor

  • Country of Origin: Japan
  • Body MoC of the Sensor: SS316 or (SS Duplexsuitable for sea waterapplications and water with chloride content)
  • Sensor comes with 9 mtrs integral cable
  • IP68 Sensor enclosure